Monitor RoCE and configuration examples for Dell Switch
*** Disclaimer ***
s2d.dk is not responsible for any errors, or for the results obtained from the use of this information on s2d.dk. All information in this site is provided as "draft notes" and "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information. Always test in a lab setup, before use any of the information in production environment.
For any reference links to other websites we encourages you to read the privacy statements of the third-party websites.
The names of actual companies and products mentioned herein may be the trademarks of their respective owners.
***
******************************************************************************
Dell Show Commands:
******************************************************************************
Microsoft references:
Show DCB and ETS for Dell Switch:
S2D# show dcb
S2D# show qos priority-groups
S2D# show qos dcb-map RDMA
S2D# show qos dot1p-queue-mapping
S2D ports
S2D# show interfaces tengigabitethernet 1/x pfc summary
S2D# show interfaces tengigabitethernet 1/x pfc statistics
S2D# show interfaces tengigabitethernet 1/x ets summary
S2D# show interfaces tengigabitethernet 1/x ets detail
S2D# show stack-unit all stack-ports all pfc details
S2D# show stack-unit all stack-ports all ets details
******************************************************************************
Dell switch configuration example (S4810):
******************************************************************************
S2D# dcb enable
*** Example #1 ***
Example for S2D/SOFS ports for Storage only:
PFC control on QoS Class 3 (SMB)
Note: Host have more pNICs
S2D# configure
S2D (Config)# dcb-map dcb-RDMA
S2D# priority-group 0 bandwidth 5 pfc off
S2D# priority-group 3 bandwidth 95 pfc on
S2D# priority-pgid 0 0 0 3 0 0 0 0
S2D# exit
*** Example #2 ***
Example for ports for Storage and Virtual Guest (VM) traffic with one Physical Network Adapter (2 Ports):
PFC control on QoS Class 3 (SMB) and Class 5 (Cluster)
S2D# configure
S2D (Config)# dcb-map dcb-RDMA
S2D# priority-group 0 bandwidth 39 pfc off
S2D# priority-group 3 bandwidth 60 pfc on
S2D# priority-group 5 bandwidth 1 pfc off
S2D# priority-pgid 0 0 0 3 0 5 0 0
S2D# exit
*** Example #3 ***
Example for Host ports for Storage and Virtual Guest (VM) traffic with one Physical Network Adapter (2 Ports):
PFC control on QoS Class 3 (SMB) and Class 7 (Cluster)
S2D# configure
S2D (Config)# dcb-map dcb-RDMA
S2D# priority-group 0 bandwidth 39 pfc off
S2D# priority-group 3 bandwidth 60 pfc on
S2D# priority-group 7 bandwidth 1 pfc off
S2D# priority-pgid 0 0 0 3 0 0 0 7
S2D# exit
Apply map to ports 0-xx
S2D# configure
S2D# interface range tengigabitethernet 0/0-xx
S2D# dcb-map dcb-RDMA
S2D# exit
Archive
-
▼
2019
(26)
-
▼
October
(13)
- RoCE Troubleshooting
- Monitor RoCE - Windows Server
- Monitor RoCE - Dell
- Monitor RoCE - Cisco
- Monitor RoCE - HPE
- Monitor RoCE - Fujitsu
- Monitor RoCE - Lenovo
- Mellanox SR-IOV
- Mellanox SR-IOV VF
- Mellanox 56 Gigabit
- Virtual Disks resources are in No Redundancy or De...
- Retire, Remove, Reset or Add Disk to Storage Pool
- Remove Node
-
▼
October